Metric Nylon Cable Glands | M12–M114
Standard Metric nylon cable glands for control panels, equipment housings and junction boxes. Select the thread size and cable range from the tables below.
- Material: Nylon body with rubber sealing insert.
- Thread sizes: M12–M63 with 1.5 mm pitch; M72, M75, M80, M88, M90, M100 and M114 with 2 mm pitch.
- Cable range: See the range for each size and configuration in the tables below.
- Protection: IP55 without a flat gasket; IP68 with the specified flat sealing washer and correct installation.
- Flat sealing washer: Not included as standard. Please specify if required.
- Documents: Product drawings, CE documentation and RoHS reports are available on request.
Sealing Options for Standard Metric Glands
The flat sealing washer (flat gasket) seals the gland-to-enclosure interface and is an optional item for this standard series. Specify it when requesting IP68. The rubber insert seals around the cable; choose the cable range using the actual cable outside diameter, not the conductor cross-section.
Metric Thread Nylon Gland Dimensional & Packaging Specifications
M12–M63: Metric Threads with 1.5 mm Pitch
| Model No. | Thread Size (Metric) | Mounting Hole Diameter(mm) | Thread Length (mm) | Thread O.D. (mm) | Max. Panel Thickness(mm) | Cable Range (mm) | Wrench Size (mm) | Standard Packaging (pcs/bag) |
| SC-M12 | M12×1.5 | Φ12.2-12.5 | 9 | 12 | 3 | 3-6.5 | 18/16 | 100 |
| SC-M12 | M12×1.5 | Φ12.2-12.5 | 9 | 12 | 3 | 2-5 | 18/16 | 100 |
| SC-M16 | M16×1.5 | Φ16.2-16.5 | 9 | 16 | 3 | 4-8 | 22/19 | 100 |
| SC-M16 | M16×1.5 | Φ16.2–16.5 | 9 | 16 | 3 | 2-6 | 22/19 | 100 |
| SC-M18 | M18×1.5 | Φ18.2-18.5 | 9 | 18 | 3 | 5-10 | 24/22 | 100 |
| SC-M18 | M18×1.5 | Φ18.2-18.5 | 9 | 18 | 3 | 3-7 | 24/22 | 100 |
| SC-M20 | M20×1.5 | Φ20.2-20.5 | 9 | 20 | 5 | 6-12 | 27/24 | 100 |
| SC-M20 | M20×1.5 | Φ20.2-20.5 | 9 | 20 | 4 | 5-9 | 27/24 | 100 |
| SC-M22 | M22×1.5 | Φ22.2-22.5 | 10 | 22 | 5 | 10-14 | 30/27 | 100 |
| SC-M22 | M22×1.5 | Φ22.2-22.5 | 10 | 22 | 5 | 6-12 | 30/27 | 100 |
| SC-M24 | M24×1.5 | Φ24.2-24.5 | 10 | 24 | 5 | 12-15 | 33/28 | 100 |
| SC-M24 | M24×1.5 | Φ24.2-24.5 | 10 | 24 | 5 | 10-12 | 33/28 | 100 |
| SC-M25 | M25×1.5 | Φ25.2-25.5 | 10 | 25 | 5 | 13-15 | 33/28 | 100 |
| SC-M25 | M25×1.5 | Φ25.2-25.5 | 10 | 25 | 5 | 8-12 | 33/28 | 100 |
| SC-M25 | M25×1.5 | Φ25.2-25.5 | 12 | 25 | 5 | 13-18 | 33/30 | 100 |
| SC-M25 | M25×1.5 | Φ25.2-25.5 | 12 | 25 | 5 | 9-16 | 33/33 | 100 |
| SC-M27 | M27×1.5 | Φ27.2-27.5 | 12 | 27 | 5 | 13-18 | 35/33 | 100 |
| SC-M27 | M27×1.5 | Φ27.2-27.5 | 12 | 27 | 6 | 9-16 | 35/33 | 100 |
| SC-M30 | M30×1.5 | Φ30.2-30.5 | 12 | 30 | 6 | 16-22 | 37/37 | 100 |
| SC-M30 | M30×1.5 | Φ30.2-30.5 | 12 | 30 | 6 | 16-20 | 37/37 | 100 |
| SC-M32 | M32×1.5 | Φ32.2-32.5 | 12 | 32 | 6 | 16-21 | 39/35 | 100 |
| SC-M32 | M32×1.5 | Φ32.2-32.5 | 12 | 32 | 6 | 13-18 | 39/35 | 100 |
| SC-M36 | M36×1.5 | Φ36.2-37 | 12 | 36 | 6 | 18-25 | 45/42 | 50 |
| SC-M36 | M36×1.5 | Φ36.2-37 | 12 | 36 | 7 | 13-20 | 45/42 | 50 |
| SC-M40 | M40×1.5 | Φ40.2-41 | 17 | 40 | 7 | 20-26 | 52/52 | 50 |
| SC-M40 | M40×1.5 | Φ40.2-41 | 17 | 40 | 7 | 22-32 | 52/52 | 50 |
| SC-M50 | M50×1.5 | Φ50.5-51 | 19 | 50 | 10 | 32-38 | 60/60 | 20 |
| SC-M50 | M50×1.5 | Φ50.5-51 | 19 | 50 | 10 | 25-36 | 60/60 | 20 |
| SC-M63 | M63×1.5 | Φ63.5-64 | 19 | 63 | 10 | 37-44 | 74/69 | 10 |
| SC-M63 | M63×1.5 | Φ63.5-64 | 19 | 63 | 10 | 29-35 | 74/69 | 10 |
M72–M114: Metric Threads with 2 mm Pitch
| Thread Size | Cable Range (mm) | Thread Length (mm) | Thread O.D. (mm) | Wrench Size (mm) |
|---|---|---|---|---|
| M72×2 | 40–55 | 26 | 72 | 85/85 |
| M75×2 | 40–55 | 25.3 | 75 | 87/79 |
| M80×2 | 55–66 | 22.2 | 80 | 93/98 |
| M88×2 | 55–66 | 22.2 | 88 | 97/97 |
| M90×2 | 66–77 | 25 | 90 | 110/120 |
| M100×2 | 80–90 | 27.7 | 100 | 110/119 |
| M114×2 | 80–90 | 28 | 114 | 115/126 |
For M72–M114, request the product drawing to check the mounting hole and allowable panel thickness. Packing quantities are confirmed with the quotation.
Request a Metric Cable Gland Quote
List each thread size, cable outside diameter, required sealing configuration and quantity. Attach your model list or enclosure drawing if available.
Cable Entries for Control Panels and Equipment
Use this range when specifying cable entries for control panels, equipment housings and junction boxes. For outdoor, wet or chemically exposed locations, provide the temperature range and details of exposure to water, sunlight, oils or chemicals. These conditions affect material and sealing selection; a matching Metric thread alone does not establish suitability.
FAQs
Check the Enclosure Before Ordering
- Threaded entry: Verify both the Metric thread diameter and pitch.
- Unthreaded entry: Check the finished hole diameter and specify the locknut needed to secure the gland.
- Panel thickness: Allow for the panel and sealing washer when checking the available thread engagement.
- Installation space: Leave room for the gland body and tightening tools, particularly where cable entries are close together.
Related Products
Related News
To specify a multi-hole cable gland, provide the number of cables, the outside diameter of each cable and the enclosure […]
Before ordering a cable gland replacement, check the entry thread, finished panel opening, available thread length and installation space. The […]
A cable may be sold under one conductor size while its finished outside diameter changes with insulation, shielding and jacket […]